Whirlpool Factory Service ManualFault Code: F22

Whirlpool Dryer Error Code F22: Exhaust Thermistor Circuit Open or Shorted

The main electronic control board detects an open or shorted exhaust thermistor circuit (resistance reading exceeds 40,000 ohms or drops below 500 ohms at room temperature).

OEM Brand: WhirlpoolAppliance: dryerVerified OEM Diagnostics
Whirlpool dryer diagnostic bench testing and technical inspection for error code F22
Whirlpool DRYER Diagnostic BenchCODE: F22
Target Appliance

dryer

OEM Certified Technical Diagnostic Tree

Diagnostic Tool Required

Digital Multimeter

Measure Ohms resistance, continuity & line voltage.

Triage Complexity

Advanced Diagnostic

4 Sequential manufacturer inspection branches.

Sequential Factory Diagnostic Tree

Perform each diagnostic step in order. Disconnect electrical power and turn off utility shutoffs before inspecting wiring or internal mechanical assemblies.

Digital multimeter measuring ohms resistance and terminal pin continuity on appliance electronic control board
Bench Testing Protocol

Multimeter Resistance & Continuity Verification

Before replacing any electronic control board or mechanical sensor, disconnect power and measure terminal resistance using a calibrated digital multimeter. Verify continuity (0 ฮฉ) across safety switches and compare sensor resistance against OEM specs in the diagnostic steps below.

Step 1: Physical & Electrical InspectionMultimeter & Visual
Action: Unplug the dryer and disconnect the exhaust thermistor wire harness located on the blower housing duct.
Bench Test: Measure resistance across the two thermistor terminals using a digital multimeter set to ohms.
Expected Standard: Approximately 11,900 ohms at 70ยฐF (21ยฐC) or 10,000 ohms at 77ยฐF (25ยฐC).
If Failed / Out of Spec:

Replace exhaust thermistor (WP8577274).

If Passed:

Proceed to Step 2.

Step 2: Physical & Electrical InspectionMultimeter & Visual
Action: Inspect the wire harness between the exhaust thermistor and the main control board for pinches, chafing, or corrosion.
Bench Test: Measure wire continuity from control board connector P4-3 and P4-6 to thermistor terminals.
Expected Standard: 0 ohms (continuous circuit with no short to chassis ground).
If Failed / Out of Spec:

Repair or replace damaged wire harness section.

If Passed:

Proceed to Step 3.

Step 3: Physical & Electrical InspectionMultimeter & Visual
Action: Inspect blower housing and exterior exhaust vent for severe lint blockage causing thermal overshoot.
Bench Test: Examine airflow damper and duct run for physical restrictions, crimps, or bird nests.
Expected Standard: Unobstructed high-velocity airflow out exterior damper.
If Failed / Out of Spec:

Clean dryer exhaust ductwork and vent hood damper.

If Passed:

Proceed to Step 4.

Step 4: Physical & Electrical InspectionMultimeter & Visual
Action: If thermistor resistance, wiring continuity, and airflow test within specifications, inspect main control board sensing circuit.
Bench Test: Check voltage drop across thermistor input pins with power restored in diagnostic mode.
Expected Standard: 5V DC reference signal from control board.
If Failed / Out of Spec:

Replace main electronic machine control board (WPW10111606).

If Passed:

Clear fault code in diagnostic test mode and run test dry cycle.

Verified OEM Replacement Parts

Cross-referenced factory part numbers for Whirlpool dryer error code F22. Always replace defective components with authentic OEM parts to maintain UL safety certification.

Component NameOEM Part NumberManufacturerStatus
Exhaust ThermistorWP8577274WhirlpoolDirect Fit OEM
Thermal FuseWP3392519WhirlpoolDirect Fit OEM
Electronic Machine Control BoardWPW10111606WhirlpoolDirect Fit OEM

Estimated Repair Cost Ranges: Whirlpool F22

Repair costs for Whirlpool dryers displaying error code F22 vary based on component damage, accessibility, and whether you self-install or dispatch a local factory-trained technician.

DIY Replacement Part

$140 โ€“ $340

Direct OEM replacement part cost (excluding tools, shipping, or diagnostic meter equipment).

Pro Diagnostic Fee

$89 โ€“ $149

Standard in-home diagnostic evaluation fee by an independent technician (typically applied toward repair).

Total Pro Repair Range

$320 โ€“ $590

Typical total job cost including in-home diagnostic, authentic OEM parts, and professional labor (60โ€“120 mins).

Pricing & Diagnostic Disclosure:

The pricing figures provided above represent broad industry averages based on nationwide market surveys and component replacement requirements. Pricing depends on multiple factors including the specific appliance brand, age, mechanical condition, diagnostic complexity, accessibility, and local labor rates. All independent repair contractors set their own independent rates and fee structures. An in-home diagnostic evaluation by an authorized technician is required to provide an exact written quote prior to any repair work.

Related Symptom Triage Guides for Whirlpool dryers

If your appliance displays code F22 alongside physical operational symptoms, consult our dedicated failure triage flowcharts:

Symptom Triage

Why Does My Dryer Have a Burning Smell During Operation?

View Triage Flowchart โ†’
Symptom Triage

Why Does My Dryer Shut Off Mid-Cycle After a Few Minutes?

View Triage Flowchart โ†’
Symptom Triage

Why Is My Dryer Drum Not Turning or Spinning?

View Triage Flowchart โ†’
Symptom Triage

Why Is My Dryer Drum Thumping or Shaking? Causes & Repair Steps

View Triage Flowchart โ†’
Engineering Service Hub

Looking for Full Dryer Repair Procedures?

Explore comprehensive diagnostic mechanics, component resistance curves, and EPA guidelines for Whirlpool units.

Dryer Repair Specs โ†’
Local In-Home Diagnostic Dispatch

Tired of Troubleshooting Code F22? Get a Local Whirlpool Technician.

If multimeter bench tests confirm component failure or you prefer a professional to safely service your high-voltage Whirlpool dryer, connect with an independent certified specialist in Colorado, Kansas, or New Mexico today.

(945) 206-7476 Urgent: (855) 796-2411Mon-Sun 7amโ€“9pm โ€ข Fast Local Dispatch
Local In-Home Service DispatchSame-Day Available

Need In-Home Diagnostic Dispatch for Code F22?

If multimeter testing confirms an internal short, failed heating element, locked motor, or burnt control board on your Whirlpool dryer, connect with an independent certified technician in your city.

dryer repair in Olathe, KS
Olathe, KS Dispatch Hub
โ†’
dryer repair in Overland Park, KS
Overland Park, KS Dispatch Hub
โ†’
dryer repair in Wichita, KS
Wichita, KS Dispatch Hub
โ†’
dryer repair in Lawrence, KS
Lawrence, KS Dispatch Hub
โ†’
dryer repair in Topeka, KS
Topeka, KS Dispatch Hub
โ†’
dryer repair in Kansas City, KS
Kansas City, KS Dispatch Hub
โ†’
dryer repair in Denver, CO
Denver, CO Dispatch Hub
โ†’
dryer repair in Colorado Springs, CO
Colorado Springs, CO Dispatch Hub
โ†’
dryer repair in Aurora, CO
Aurora, CO Dispatch Hub
โ†’
dryer repair in Fort Collins, CO
Fort Collins, CO Dispatch Hub
โ†’
dryer repair in Lakewood, CO
Lakewood, CO Dispatch Hub
โ†’
dryer repair in Boulder, CO
Boulder, CO Dispatch Hub
โ†’
dryer repair in Albuquerque, NM
Albuquerque, NM Dispatch Hub
โ†’
dryer repair in Las Cruces, NM
Las Cruces, NM Dispatch Hub
โ†’
dryer repair in Rio Rancho, NM
Rio Rancho, NM Dispatch Hub
โ†’
Serving over 120+ cities across Colorado, Kansas, and New Mexico. View all municipal service areas โ†’
Dispatch: (945) 206-7476 Urgent Scenario: (855) 796-2411

Frequently Asked Questions: Whirlpool F22

What causes Whirlpool dryer error code F22?

The main electronic control board detects an open or shorted exhaust thermistor circuit (resistance reading exceeds 40,000 ohms or drops below 500 ohms at room temperature).

Can I reset the F22 code by unplugging the dryer?

While disconnecting power for 5 minutes may temporarily clear the display control memory, the F22 code will reoccur once the microcontroller detects the mechanical or electrical fault again.

What OEM replacement parts are required for Whirlpool F22?

Common OEM replacement components include: Exhaust Thermistor (OEM #WP8577274), Thermal Fuse (OEM #WP3392519), Electronic Machine Control Board (OEM #WPW10111606).

How much does it cost to fix Whirlpool dryer error code F22?

Professional repair for Whirlpool dryer error code F22 typically averages $320 โ€“ $590 in total (including an estimated diagnostic fee of $89 โ€“ $149 plus labor and authentic OEM components). Sourcing authentic replacement parts yourself costs approximately $140 โ€“ $340. Final prices depend on model specifics, local labor rates, and physical technician inspection.

Dispatch: (945) 206-7476 Urgent: (855) 796-2411