Free tool

Appliance Error Code Lookup

Type the code on your display to see what it means and how to check it. Covers 90 codes from Bosch, Frigidaire, GE, LG, Samsung, Whirlpool. No code? Describe the problem instead, like "dryer not heating".

E09Bosch · Dishwasher

Bosch Dishwasher E09

The integrated flow-through heating element inside the main wash circulation heat pump has suffered an open circuit or burned internal resistive trace.

See diagnostic steps
E14Bosch · Dishwasher

Bosch Dishwasher E14

The reed switch sensor on the left-side water matrix impellor flow meter is not sending pulses to the control board despite water entering the tub.

See diagnostic steps
E15Bosch · Dishwasher

Bosch Dishwasher E15

The safety styrofoam float switch located in the bottom plastic base trough has detected accumulated water, activating continuous drain pump operation and halting incoming fill.

See diagnostic steps
E20Bosch · Dishwasher

Bosch Dishwasher E20

The main wash circulation motor windings exhibit abnormal resistance or an open circuit, preventing wash water pressurization.

See diagnostic steps
E22Bosch · Dishwasher

Bosch Dishwasher E22

The electronic control module detects residual water in the tub sump at the conclusion of a wash phase or excessive hydraulic restriction caused by a clogged micro-filter, unlatched pump cover, or sluggish drainage.

See diagnostic steps
E24Bosch · Dishwasher

Bosch Dishwasher E24

The main power module senses abnormal current draw or incomplete water evacuation from the BLDC synchronous drain pump during the initial 1-minute pre-drain sequence, usually caused by a loose impeller cap, blocked non-return valve, or pinched drain line.

See diagnostic steps
E25Bosch · Dishwasher

Bosch Dishwasher E25

The drain pump motor cannot reach target rotational velocity or the pump cover locking clip is dislodged, causing fluid cavitation.

See diagnostic steps
E01Bosch · Dryer

Bosch Dryer E01

Internal thermal sensors detect excessive temperature rise across the blower housing caused by an obstructed lint screen or clogged exterior exhaust duct.

See diagnostic steps
E06Bosch · Dryer

Bosch Dryer E06

The electronic control module detects no temperature increase during the drying cycle, or the safety thermal limiter fuse has opened.

See diagnostic steps
E08Bosch · Dryer

Bosch Dryer E08

On ventless heat-pump and condensation dryers, the water reservoir float switch detects excessive liquid that the condensate pump failed to evacuate.

See diagnostic steps
E12Bosch · Dryer

Bosch Dryer E12

The control module detects restricted airflow across the condenser unit or exhaust duct, causing excessive internal temperatures.

See diagnostic steps
Er1Bosch · Oven & Range

Bosch Oven & Range Er1

The main electronic oven control module senses an open circuit or infinite resistance across the oven cavity PT1000 / NTC temperature probe.

See diagnostic steps
Er2Bosch · Oven & Range

Bosch Oven & Range Er2

The electronic clock timer control detects a continuously closed or shorted touch key for greater than 60 consecutive seconds.

See diagnostic steps
Er3Bosch · Oven & Range

Bosch Oven & Range Er3

The safety high-limit thermal cutoff switch has opened or the RTD oven temperature sensor detects cavity temperatures exceeding 650°F during normal baking.

See diagnostic steps
Er6Bosch · Oven & Range

Bosch Oven & Range Er6

The electronic control module detects that the motorized door latch switch did not change state within the programmed timeout period during lock or unlock sequence.

See diagnostic steps
E01Bosch · Refrigerator

Bosch Refrigerator E01

The electronic control module detects an open circuit or shorted reading from the fresh food refrigerator compartment temperature sensor (NTC).

See diagnostic steps
E02Bosch · Refrigerator

Bosch Refrigerator E02

The NTC thermistor sensor clipped to the freezer evaporator coil is reporting an open circuit, short circuit, or erratic reading outside normal range.

See diagnostic steps
E03Bosch · Refrigerator

Bosch Refrigerator E03

The electronic control module detects an open circuit, short, or invalid resistance from the evaporator defrost NTC temperature sensor.

See diagnostic steps
E10Bosch · Refrigerator

Bosch Refrigerator E10

The door-mounted user interface display panel has lost serial communication with the master inverter power control module in the machine compartment.

See diagnostic steps
E17Bosch · Washer

Bosch Washer E17

The front-load washing machine did not reach the target water level in the tub within the programmed 6-minute fill timeout window.

See diagnostic steps
E18Bosch · Washer

Bosch Washer E18

The main electronic control module senses that the water level did not drop to empty within 9 minutes of drain cycle start, indicating pump blockage or failure.

See diagnostic steps
E20Bosch · Washer

Bosch Washer E20

The wash control board detects an unexpected temperature sensor reading or zero temperature rise during an active wash heating cycle.

See diagnostic steps
E23Bosch · Washer

Bosch Washer E23

The safety styrofoam float switch located in the bottom metal base pan is elevated by collected leak water, triggering AquaStop shutoff.

See diagnostic steps
E25Bosch · Washer

Bosch Washer E25

The emergency float switch in the bottom plastic base pan of the washing machine has detected liquid, locking the water valves and activating drain.

See diagnostic steps
E29Bosch · Washer

Bosch Washer E29

The machine detected an unexpected drop in fill pressure or flow rate during mid-cycle wash or rinse fill operations.

See diagnostic steps
i10Frigidaire · Dishwasher

Frigidaire Dishwasher i10

The electronic pressure sensor detects that the water level in the sump basin failed to reach minimum operating threshold within the allotted fill period.

See diagnostic steps
i20Frigidaire · Dishwasher

Frigidaire Dishwasher i20

The electronic control board senses an open pressure switch circuit after draining, indicating water did not evacuate within allowable drain cycle time.

See diagnostic steps
i30Frigidaire · Dishwasher

Frigidaire Dishwasher i30

The safety flood protection float switch in the bottom plastic drip tray detected standing water, halting cycle operation and running drain pump continuously.

See diagnostic steps
i40Frigidaire · Dishwasher

Frigidaire Dishwasher i40

The main control board detects an analog voltage signal from the pressure transducer that is out of calibration range or completely shorted.

See diagnostic steps
i50Frigidaire · Dishwasher

Frigidaire Dishwasher i50

The main control board detects wash pump motor over-current or a shorted motor drive triac, stopping cycle execution to prevent board burnout.

See diagnostic steps
E4AFrigidaire · Dryer

Frigidaire Dryer E4A

The electronic control board detects that the maximum programmed dry cycle duration (typically 90–120 minutes) was exceeded without clothes drying properly.

See diagnostic steps
E5BFrigidaire · Dryer

Frigidaire Dryer E5B

The electronic control board detects that the exhaust thermistor temperature does not rise after the heating element or burner is commanded on.

See diagnostic steps
E64Frigidaire · Dryer

Frigidaire Dryer E64

The electronic control board detects zero current draw across the electric heating element circuit during a designated heat cycle.

See diagnostic steps
E68Frigidaire · Dryer

Frigidaire Dryer E68

The electronic control board detects that one of the touch keys on the membrane interface has been shorted or pressed continuously for > 30 seconds.

See diagnostic steps
F10Frigidaire · Oven & Range

Frigidaire Oven & Range F10

The electronic oven control (EOC) board senses that the oven cavity temperature is rising uncontrolled or has exceeded safe threshold while idle or baking.

See diagnostic steps
F11Frigidaire · Oven & Range

Frigidaire Oven & Range F11

The electronic oven control (EOC) board senses a shorted or stuck key contact on the touch membrane matrix for greater than 32 seconds.

See diagnostic steps
F30Frigidaire · Oven & Range

Frigidaire Oven & Range F30

The electronic oven control (EOC) board detects an open circuit or infinite resistance across the oven cavity temperature sensor probe.

See diagnostic steps
F31Frigidaire · Oven & Range

Frigidaire Oven & Range F31

The electronic oven control board detects resistance below 900 ohms across the oven RTD temperature sensor probe, indicating a shorted probe or wiring.

See diagnostic steps
F90Frigidaire · Oven & Range

Frigidaire Oven & Range F90

The motorized door latch assembly failed to reach the target locked or unlocked microswitch position within the programmed 60-second limit.

See diagnostic steps
dFFrigidaire · Refrigerator

Frigidaire Refrigerator dF

The electronic defrost control detects that the evaporator defrost heater failed to raise the defrost bimetal thermostat temperature within maximum allowed time.

See diagnostic steps
SY CEFrigidaire · Refrigerator

Frigidaire Refrigerator SY CE

The front door dispenser touch display panel is not receiving valid digital communication packets from the main power board in the rear cabinet.

See diagnostic steps
SY CFFrigidaire · Refrigerator

Frigidaire Refrigerator SY CF

The main electronic power board (located beneath the cabinet or in compressor bay) loses serial communication with the user interface display board in the door.

See diagnostic steps
SY EFFrigidaire · Refrigerator

Frigidaire Refrigerator SY EF

The main electronic control board detects no current draw or tachometer feedback from the freezer evaporator fan motor circuit.

See diagnostic steps
E11Frigidaire · Washer

Frigidaire Washer E11

The main electronic control board detects that the wash tub did not reach the target water level within 8 minutes of water inlet valve opening.

See diagnostic steps
E21Frigidaire · Washer

Frigidaire Washer E21

The main electronic control board detects that water did not drain from the wash tub within the allowable 4.5-minute drain cycle timeout.

See diagnostic steps
E41Frigidaire · Washer

Frigidaire Washer E41

The main control board senses that the front door switch contacts are open when a wash cycle is commanded to start.

See diagnostic steps
E43Frigidaire · Washer

Frigidaire Washer E43

The main control board detects a shorted or failed PTC heating element inside the door lock assembly or a burned board lock triac.

See diagnostic steps
E47Frigidaire · Washer

Frigidaire Washer E47

The main control board attempts to energize the door lock mechanism but detects an open circuit in the PTC lock solenoid loop.

See diagnostic steps
E52Frigidaire · Washer

Frigidaire Washer E52

The motor control board (MCB) energizes the drive motor but receives zero rotational speed feedback pulses from the motor tachometer generator coil.

See diagnostic steps
E59Frigidaire · Washer

Frigidaire Washer E59

The main electronic control board (in console) cannot establish or maintain serial data communication with the motor control inverter board (in base).

See diagnostic steps
FTDGE · Dishwasher

GE Dishwasher FTD

The electronic control module detects that water remains in the wash tub sump after the drain pump runs for the maximum drain duration.

See diagnostic steps
H2OGE · Dishwasher

GE Dishwasher H2O

The electronic control module senses low or zero water entering the dishwasher tub during fill sequence, detected by the flood switch and turbidity sensor timeout.

See diagnostic steps
001GE · Dryer

GE Dryer 001

The main electronic control board senses an open circuit in the inlet temperature thermistor circuit (located near the heating element housing).

See diagnostic steps
004GE · Dryer

GE Dryer 004

The main electronic control board commanded the drive motor to run but did not detect motor centrifugal switch closure or rotational feedback within 5 seconds.

See diagnostic steps
F2GE · Oven & Range

GE Oven & Range F2

The electronic oven control (EOC) board senses that the oven cavity temperature exceeded 590°F during normal bake or 990°F during self-clean cycle.

See diagnostic steps
F3GE · Oven & Range

GE Oven & Range F3

The electronic oven control (EOC) detects an open circuit or high resistance (>2,500 ohms) in the RTD temperature probe circuit during bake or broil cycle.

See diagnostic steps
ERR 01GE · Refrigerator

GE Refrigerator ERR 01

The main electronic control board does not detect rotational tachometer speed feedback pulses from the DC evaporator fan motor for more than 2 minutes.

See diagnostic steps
ERR 02GE · Refrigerator

GE Refrigerator ERR 02

The main electronic control board detects an open or shorted thermistor circuit in the fresh food refrigerator compartment (resistance reading out of range).

See diagnostic steps
26GE · Washer

GE Washer 26

The main electronic control board detected an unrecoverable unbalanced load condition during the spin cycle, tripping the optical or 3D accelerometer balance sensor.

See diagnostic steps
3GE · Washer

GE Washer 3

The washer control board failed to sense the tub water level dropping to empty within 7 minutes of drain pump activation.

See diagnostic steps
AELG · Dishwasher

LG Dishwasher AE

The safety float sensor switch mounted in the bottom plastic drip tray detected standing water, halting cycle operation and running drain pump continuously.

See diagnostic steps
OELG · Dishwasher

LG Dishwasher OE

The main control board detected that water level did not drop below empty threshold after drain pump ran during drain interval.

See diagnostic steps
d90LG · Dryer

LG Dryer d90

LG FlowSense duct monitor detects that 90% of the dryer's exhaust airflow is blocked by lint accumulation, crushed venting, or a stuck exterior damper.

See diagnostic steps
tE1LG · Dryer

LG Dryer tE1

The main electronic control board detects that the exhaust thermistor sensor circuit resistance is either zero ohms (short circuit) or infinite ohms (open circuit), preventing temperature regulation.

See diagnostic steps
F3LG · Oven & Range

LG Oven & Range F3

The main electronic oven PCB detects an open circuit in the oven temperature sensor probe circuit during heating operation.

See diagnostic steps
F9LG · Oven & Range

LG Oven & Range F9

The main electronic oven control board detects that the oven cavity temperature failed to rise above 150°F (65°C) within 5 to 7 minutes after initiating a Bake, Broil, or Convection cycle.

See diagnostic steps
Er dHLG · Refrigerator

LG Refrigerator Er dH

The evaporator defrost thermistor did not rise above 41°F (5°C) within 80 minutes of the defrost heater being energized by the main control board.

See diagnostic steps
Er FFLG · Refrigerator

LG Refrigerator Er FF

The main control board does not receive rotational feedback pulses (RPM signal) from the freezer evaporator fan motor for more than 115 seconds during compressor run.

See diagnostic steps
LELG · Washer

LG Washer LE

The main PCB detects that the direct drive motor rotor is locked, overloaded, or the Hall effect rotor position sensor (RPS) is sending erratic feedback signals.

See diagnostic steps
OELG · Washer

LG Washer OE

The electronic main board detected that the washer did not drain the tub water below reset frequency within 10 minutes of starting the drain cycle.

See diagnostic steps
4CSamsung · Dishwasher

Samsung Dishwasher 4C

The main control board detects that water did not enter the dishwasher tub to operating level within the timeout period, or the flow meter sensor failed to register pulses.

See diagnostic steps
LCSamsung · Dishwasher

Samsung Dishwasher LC

The moisture leak sensor located in the bottom drip tray pan detects water or conductive liquid, locking the dishwasher in continuous drain mode to prevent flooding.

See diagnostic steps
FESamsung · Dryer

Samsung Dryer FE

The main electronic control board detects that the incoming AC electrical supply frequency does not match 60Hz (typical for North America), indicating noisy power or board defect.

See diagnostic steps
hESamsung · Dryer

Samsung Dryer hE

The dryer detects an invalid heating condition—either temperature rising too fast due to blocked exhaust or no heat generated due to an open element or tripped thermal limit.

See diagnostic steps
C-20Samsung · Oven & Range

Samsung Oven & Range C-20

The main electronic oven control PBA board detects an open circuit or reading above 400°C from the oven cavity temperature sensor (RTD probe).

See diagnostic steps
C-21Samsung · Oven & Range

Samsung Oven & Range C-21

The electronic control board detects an open or shorted sub-temperature sensor or temperature sensing circuit fault in double-oven / duo-flex partition cavity models.

See diagnostic steps
22ESamsung · Refrigerator

Samsung Refrigerator 22E

The main control board detects a lack of RPM feedback signal pulses from the fresh food compartment evaporator fan motor, frequently caused by frost buildup around fan blades.

See diagnostic steps
25ESamsung · Refrigerator

Samsung Refrigerator 25E

The main electronic control board senses that the fresh food evaporator defrost heater failed to heat the evaporator sensor above target cutoff temperature during defrost cycle.

See diagnostic steps
4CSamsung · Washer

Samsung Washer 4C

The electronic control module detects that water is not entering the tub or water level has not reached target threshold after 10 minutes of valve activation.

See diagnostic steps
5CSamsung · Washer

Samsung Washer 5C

The washer fails to drain the wash water below the empty water level reset point within 10 to 15 minutes of drain pump activation.

See diagnostic steps
F6E4Whirlpool · Dishwasher

Whirlpool Dishwasher F6E4

The float switch circuit is detected open during cycle operation, indicating that the overfill safety float has tripped or the base drip pan leak detection float is engaged.

See diagnostic steps
F8E1Whirlpool · Dishwasher

Whirlpool Dishwasher F8E1

The electronic control board detects that the wash tub did not fill to operating depth within the allotted time, or the optical water indicator (OWI) sensed low water level.

See diagnostic steps
F22Whirlpool · Dryer

Whirlpool Dryer F22

The main electronic control board detects an open or shorted exhaust thermistor circuit (resistance reading exceeds 40,000 ohms or drops below 500 ohms at room temperature).

See diagnostic steps
F30Whirlpool · Dryer

Whirlpool Dryer F30

The control board senses an excessive temperature rise delta between the inlet and exhaust thermistors, indicating dangerously restricted exhaust airflow.

See diagnostic steps
F3E0Whirlpool · Oven & Range

Whirlpool Oven & Range F3E0

The electronic oven control (EOC) board senses an open circuit in the oven temperature sensor (RTD probe) circuit while bake, broil, or clean cycle is commanded.

See diagnostic steps
F5E0Whirlpool · Oven & Range

Whirlpool Oven & Range F5E0

The electronic control detects that the motorized door latch switch contacts do not open or close within the timeout period during clean cycle initiation or door lock sequence.

See diagnostic steps
E01Whirlpool · Refrigerator

Whirlpool Refrigerator E01

The main electronic control board is unable to read temperature resistance from the fresh food compartment thermistor due to an open circuit, short to ground, or sensor drift.

See diagnostic steps
E02Whirlpool · Refrigerator

Whirlpool Refrigerator E02

The main electronic control board detects an open or shorted defrost thermistor on the freezer evaporator coil, preventing automated adaptive defrost cycles.

See diagnostic steps
F02Whirlpool · Washer

Whirlpool Washer F02

The central control unit (CCU) detected that the drain pump ran for longer than 8 minutes without the pressure transducer signaling an empty water level.

See diagnostic steps
F08Whirlpool · Washer

Whirlpool Washer F08

The machine detects that water level has not reached the minimum target threshold after 13 minutes of continuous inlet valve actuation.

See diagnostic steps
Dispatch: (945) 206-7476 Urgent: (855) 796-2411